Home ProductsAir Driven Double Diaphragm Pump

Low Pressure Industrial Air Operated Diaphragm Pumps Dual Diaphragm Pump 12.3 Kg

China BOGEN PUMPS certification
China BOGEN PUMPS certification
BA50 IS GOOD FOR NOW

—— work well

Good job, thank you for giving me a great vacation. Best Wishes, Vinod

—— Vinod Bernardo

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service

—— Mr Hussain

I'm Online Chat Now

Low Pressure Industrial Air Operated Diaphragm Pumps Dual Diaphragm Pump 12.3 Kg

Low Pressure Industrial Air Operated Diaphragm Pumps Dual Diaphragm Pump 12.3 Kg
Low Pressure Industrial Air Operated Diaphragm Pumps Dual Diaphragm Pump 12.3 Kg

Large Image :  Low Pressure Industrial Air Operated Diaphragm Pumps Dual Diaphragm Pump 12.3 Kg

Product Details:
Place of Origin: China
Brand Name: BSK
Model Number: BSKA25AL-P99-A
Payment & Shipping Terms:
Minimum Order Quantity: 10 Unit(s)
Price: Negotiable
Packaging Details: Carton
Delivery Time: 5days
Payment Terms: FOB T/T
Supply Ability: 1000 Unit(s) Per Month
Guarantee:: one year
Detailed Product Description
Production: Double Air Driven Diaphragm Pump Feature: Non Leakage
Application: Chemical Industry Maximum Flow Rate: 192l/min
Application: Universal Material: Cast Iron
High Light:

twin diaphragm pump

,

double acting diaphragm pump

Low Pressure Casting Steel Diaphragm Pump Corrosion Resistant

 

Double Air Driven Diaphragm Pump Introduction

 

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

 

The diaphragm pump offers high volume delivery even at low air pressure and a b road range of material compatibility options available.Refer to the model and option chart.The pump is provided with the modularized air motor and fluid section.

The air operated diaphragm pump alternately generates the intake fluid pressure and positive fluid pressure in the fluid chamber by using the pressure difference in the air chamber. The ball valve can ensure the forward flow of fluid.

Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pres -sure and will stop cycling once maximum line pressure is reached (dis -pensing device closed) and will resume pumping as needed.

 

Double Air Driven Diaphragm Pump Parameters

 

Item Description Unit Reference Figure
1 Maximum air inlet pressure Mpa 0.83
2 Maximum flow rate L/Min 192
3 Maximum lift M 70
4 Maximum outlet pressure Mpa 0.83
5 Maximum particle size mm 3
6 Weight kg 12.3
7 Noise level db <70

 

Double Air Driven Diaphragm Pump Specifications

 

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium
4. Material:Cast steel,Alu,SS,PP

 

 

A 2 5 X X - X X X - X   (model selection)

 

Form of pipe mouth:A-BSP B-NPT(F) C-Flange  

Diaphragm material:9 – Santoprene H – Hytrel   T - PTFE/Santoprene  

Ball material:9 -Santoprene H – Hytre T – PTFE A - Acetal  

Ball seat material:P/K –Polypropylene/Kynoar SS –Stainless Steel  

Pump material: SS –Stainless Steel AL –Aluminum Alloy   CI- Carbon Steel P/K –Polypropylene/Kynoar

 

 

 

 

Maximum Applied Temperature Limits (diaphragm / ball / seal material)  

 

 

Acetal ···············································40°-         150°F        (4.4- 65.5°C)  

Santoprene·········································-40°- 225°F (-40°- 107.2°C)   ·················································40°- 220°F (4.4°- 104°C)   Nitrile··················································10°- 180°F (-12°- 82°C)   Viton···················································-40°- 350°F (-40°-176.6°C)   Hytrel···················································-20°-150°F (-12°- 93°C)   Kynar···················································10°-200°F (-28.9°- 65.5°C)   Polypropylene···········································32°- 175°F (0-79.4°C)

 

 

1”  Flow diagram

 

Low Pressure Industrial Air Operated Diaphragm Pumps Dual Diaphragm Pump 12.3 Kg 0

 

 

 

Requirements for Air and Lubrication

 

 

Low Pressure Industrial Air Operated Diaphragm Pumps Dual Diaphragm Pump 12.3 Kg 1EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage.

  • A filter capable of filtering out particles larger than 50 microns should be used on the air supply. There is no lubrication required other than the “O” ring lubricant which is applied during assembly or repair.
  • If lubricated air is present, make sure that it is compatible with the “O” rings and seals in the air motor section of the pump.

 

 
 

OPERATING INSTRUCTIONS

 

  • Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
  • Disconnect the air supply from the pump if it is to be inactive for a few hours.
  • The outlet material volume is governed not only by the air supply but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
  • When the diaphragm pump is used in a forced -feed (flooded inlet) situation, it is recommended that a “Check Valve” be installed at the air inlet.
  • Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration.

 

 

Maintenance

 

  • Please refer to the component schematic in the assembly drawings to look up the serial numbers and names of parts and grasp the information of parts and maintenance service pack.
  • Some BSK parts are marked as "wearing parts", which can conduce to quick service and downtime reduction.
  • Service kits are divided to service two separate diaphragm pump functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SEC -TION is divided further to match typical part MATERIAL OPTIONS.
  • Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and foreign matter during service disassembly and reassembly.
  • Keep good records of service activity and include pump in preven -tive maintenance program.
  • Before disassembling, empty captured material in the outlet man -ifold by turning the pump upside down to drain material from the pump.

 

 